OPUS B2e

Are you looking for an HMI with high performance, perfect readability and customer-friendly handling regarding installation and programming? Then, the B series from Topcon Electronics is the right choice, even for your demanding applications!

In addition to the already known B series devices, two more are added now. You can look forward to two entry-level displays with 4,3" and 7". The simple design of the existing B devices is maintained, as well as the optically bonded display. In comparison to the existing brothers from 5” to 10”, the B2 and the B2+ will come along with an i.MX6 ULL processor with up to 528 MHz, 2 GB mass storage and 256 MB RAM.

The HMIs impress users with their terrific price-performance ratio, and it’s still extensive range of features. A screen brightness of up to 900 cd/m² allows readability even in direct sunlight. The capacitive touchscreen and the fully guaranteed reading angle of up to 80 degrees ensure a smooth operation.

Download data sheet BASIC Version

Download data sheet FULL Version



Technical Data

Housing

Orientation landscape or portrait
W 122,7 x H 89 x D 36 mm excl. connector and cables


Glas, PC/ABS
Autotex XEF200

Memory

256 MB DDR3 RAM
3 GB eMMC Mass storage

Operating System

Linux Kernel 6.1.45 or higher

Certificates

CE mark
E1 Type approval

Display

4.3", 15:9 TFT
480x 272 px, 800 cd/m²
Contrast ratio 800:1

User Interface

Touchscreen

Environmental Conditions

Temperatures:
operating -30° to +75°C
storage -40° to +85°C
Protection: IP 66, IP 67
Mechanical Shock: Level 2
Random Vibration: Level 2
Sinusoidal Vibration: Level 2



Connectors

Main: Deutsch DT06-08SA 8 pin

Signals

Buzzer, approx. 92 dB(A)

Interfaces

2 x CANbus ISO 11898
CAN specification 2.0 B active
1 USB 2.0, Type C, high speed

Programming Environment

OPUS Projektor 2024 or higher (option with ISOBUS UT Plugin)
Codesys-Tools (3.5 SP 19 or higher)
C++/Qt

Processor

32-bit, 528MHz
Freescale® I.MX6ULL™

Power Supply

9 … 36 V DC

Supported Protocols

CANopen®
CANfreestyle (CAN Layer 2)
J1939

Order information